DESIGN PARAMETERS

STANDARD

OPTIONAL

Armature Voltage

440 V

Max. 470 V upto frame 132,

Max. upto 600 V for frame 160

Field Voltage

220 V

Max. upto 500 V

Excitation Type

Shunt

Series

Insulation

Class 'F'

Class 'H'

Type of Mounting

IM B3

IMB35, IMV1, IMV3

Degree of Protection

IP 23

IP 54 with IC 37/IP 55

Arrangement of T. Box

RSH from DE side

Any other arrangement

Tacho mtg. Provision

DTG 4000

Any other

Type of mounting of Blower

Top on NDE side

Any other Mounting

Air Flow Direction

From NDE to DE

From DE to NDE

Air Filter

Nil

Dry type filter

Air Flow Switch

-

Ventcaptor air flow monitor

Bearings

Ball Bearings

With regreasing facility.

For high cantilever forces

Shaft End

With keyway, Balancing with full Key

 

Space Heater

-

230 V, 1 PH

Thermister

-

For trip. for alarm and trip

Brush Length Limit Value

-

Micro switch, potential free signal

Paint Finish

-

Primer only, any other shade

 

FORCED COOLING DETAILS

FRAME

COOLING AIR

FLOW IN m3/sec

REQUIRED

PRESSURE

HEAD IN miliBar

100U & 100A

0.045

3

100S TO 100L

0.06

5

112S & 112M

0.07

5

112L

0.08

6.5

132S TO 132L

0.09

5

160 TO 160L

0.2

13

180

0.3

13.5

200

0.35

12.5

225

0.5

16

250

0.6

15

280

0.75

16

 

The noise levels of the motors have been calculated in accordance with DIN EN 21 680 and are well below the values permitted by EN 60034 - 9.

They have been achieved both by means of design measures and by optimising the magnetic circuit and the seperately driven fans

 

The blowers of D.C. Motors have three phase motors with wide range of winding and supply voltages. The blower motors are selected strictly in accordance with the air quantity required and ensures cool running of motors under the specified operating loads / overloads. The terminal box of blower motors are easily assessible.
 

BRUSH LIFETIME

FRAME

TIME IN Hrs.

Upto 160

15000

180

14000

200

12500

225

11000

250

11000

280

11000


BRUSH MATERIAL COMMUTATION :

Practically sparkless commutation with converter feeding, even under overload conditions is achieved. As a result, the brushes have an extremely long life.

 

NOISE LEVEL

FRAME

TIME IN Hrs.

100

65

112

65

132

68

160

71

180

73

200

74

225

77

250

79

280

81

 

 

 

Powered By: calcuttayellowpages.com (P) Ltd.